A little something for Truckie Tuesday
Written by firestudent1
Posted in Drills, Truck Tips
5 Comments
Recent Comments
- Boston’s Ladder Culture | Open Public Safety Institute on Boston’s Ladder Culture
- A.C.T now! | Open Public Safety Institute on A.C.T now!
- Setting Up a Hoseline For Success | Open Public Safety Institute on Setting Up a Hoseline For Success
- Roger Vivier Outlet on SCBA Familiarization
- Roger Vivier Outlet on Communication and Technique are Componets of Fireground Search
Recent Posts
Follow Firefighter Basics
Tags Across FireEMSBlogs.com
ambulance
Building construction
Building Fire
Christopher Naum
Collapse
Command Fire Apparatus
Dave Statter
destroyed
emergency
EMS
EMT
engine
extrication
fdny
fire
fire blogs
Fire Critic
FireCritic.com
fire department
firefighter
firefighters
firefighting
Fires
fire service
Fire Truck Blog
firetruckblog.com
fossilmedic
Glenn Usdin
House Fire
IronFiremen.com
leadership
LODD
Maryland
paramedic
rescue
Rhett Fleitz
safety
Sellfiretrucks.com
social media
South Carolina
STATter911.com
Structure Fire
Training
video
Willie Wines Jr.
![]() This blog is part of the Emergency Services Ad Network. For marketing opportunities, please click here |
FireEMSBlogs.com Community
- A Firefighters Own Worst Enemy
- Ambulance Driver Files
- Ash & Dreams
- Backstep Firefighter
- Command Safety
- Fire Critic
- Fire Daily
- Fire Geezer
- Fire Law
- Firefighter Blog
- Firehouse Zen
- Iron Firemen
- Life Under the Lights
- Medic 22
- Medic Three
- Pink Warm & Dry
- Prehospital 12-Lead ECG
- Raising Ladders
- Rescuing Providence
- S.A.F.E. Firefighter
- South Carolina on Fire
- STATter 911
- Street Watch
- The Company Officer
- The Fire PIO
- Tiger Schmittendorf
- TurnOut Blog
Blogroll
- A Firefighters Worst Enemy
- A-Vision
- Backstep Firefighter
- Backwards and Stupid
- Brotherhood Instructors
- Buildings On Fire
- Charleston FF Support Team
- Fire Department Training Network
- Fire Engineering
- Fire Officer Mentor
- Fire Officer Trust
- Fire Rescue Magazine
- Fire Town Training Specialists
- Firefighter Close Calls
- Firehouse
- Firehouse Zen
- Fools
- Haz- Mat Ohio
- HP Firefighter
- National Firefighter Near Miss Program
- OnScene Training Associates
- PL Vulcan Fire Training
- SC On Fire
- Statter 911
- TES2 Training.com
- The Company Officer
- Traditons Training
- Urban Firefighter Magazine
- Vent Enter Search
- WordPress.com
- WordPress.org









Good demonstration.
I would respectfully submit that we don’t drop the cut pieces of roof in our victims and or Engine Companies.
If you want to disorientate your Engine crew hit them with 2 foot by 4 foot piece of roof. Alot of our roofs have several layers of shingles (they skip that strip it before you put a new roof on) and the pieces are heavy.
In newer commercial buildings a drop ceiling is no match to stop a large section of roof.
Now for a bit of Ripple’s Believe It or Not…
During a Truck Ops class some years back we were working on a roof composed of the following.
Tar and Rock
Lighweight concrete
Tin.
3 Saws on the roof
#1 K-950 with a universal blade (the type that looks like small pieces clued around the blade not a carbine tip style)
#2 Tempest Ventmaster
#3 K-950 with a Diamond tip blade.
Of the 3 which would you think the fasters cutter?
If you chose the K950 combos sorry you out of this round.
I had ran saws in the logging industriy since the 80s and would have bet on the K950 all day long.
Utilizing the deepth gauge on the Ventmaster and “pushing” the saw away from you while rest the deepth gauge on the roof you cut as fast as you cared to walk on roof next to a hole.
Was the chain shot, yes it would barely mark a piece of wood when got done. But it did out perform the rest with K-950 #1 coming in right behind the Ventmaster.
Kevin great points. Thank you for pointing that out. Sometimes in the hast of trying to post something that firefighters can use right away, things that can be important such as what you are stating gets forgotten. Thank you for commenting and we hope you will continue to contribute to our site.
OK Kevin first, thanks for commenting, I don’t want to sound critical, well maybe a little. The cut should be over the fire, not the firefighters. The video does not show the hopefully large amounts of products of combustion that should be coming through the hole. More than 2 guys on a roof would be a luxury in most departments.
What do you suggest we do with the cut out piece? Do you have a trick to moving the panel aside that works reliably? You can’t expect it to hang by the nails and drop when it’s ready later as the fire evolves. What if it isn’t even wood? Some crappy metal decking that is puddle welded won’t have much to keep it in place after a cut.
And my last question, when would you cut a concrete roof? Besides the potential dangers associated with that, aren’t there more productive ventilation techniques that could be used than doing a clean breach on the roof?
Don’t get me wrong, I appreciate the comment, It just raises more questions for me and maybe some other readers too. Be safe.
anchorpoint1 Says:
April 28, 2010 at 8:08 am
I hope this copies and pastes correctly. I put Anchorpoint in italics and my reply in bold. Not yelling just trying show the reply.
OK Kevin first, thanks for commenting, I don’t want to sound critical, well maybe a little.
Asking questions in not being critical it is just asking questions. It is how we learn. You are correct the cut should be over the fire, keyword should. But so we are directly over the fire and that fire is in some say racked storage or the fire is actually a box truck. We drop our piece through it bounces off either of these two objects and cart wheels off a little more than is length. If you cut commercial holes like I do that is at 10 feet or better. Or maybe the pieces hangs and doesn’t fall till later…..
The cut should be over the fire, not the firefighters. The video does not show the hopefully large amounts of products of combustion that should be coming through the hole. More than 2 guys on a roof would be a luxury in most departments.
This a commercial building more than two members on the roof is a necessity not a luxury.
Sending too few to the roof is as big a hazard as too many. The operation takes longer and members get tired faster being subject to error. If there is not enough people arriving, dispatch more. Cutting the roof is, as the late Chief Tom Brennan phrased, which I have not heard many say anymore part of “Making the Building Behave”. Cutting on hole and stopping the effect of smoke banking down and the fire rolling through the attic or cockloft has a far greater benefit than having 2 roving chiefs and 2 safety officer walking around listening to one hook and saw working above and wondering if they will ever get down. It kills me to see five Chiefs standing in front of fire, while their understaffed engine and trucks struggle along. Hey Chief, you are supervisor go supervise or go work. The best Chiefs I know have dirty white helmets.
What do you suggest we do with the cut out piece? Do you have a trick to moving the panel aside that works reliably? You can’t expect it to hang by the nails and drop when it’s ready later as the fire evolves.
Flat roof, leave it up there, if you are worried about it getting blown off by a master stream later, you need to take the other roof junk off with you to. We are talking about a flat roof here not pitched.
What if it isn’t even wood? Some crappy metal decking that is puddle welded won’t have much to keep it in place after a cut.
Pull/roll it back leave part of it holding and take care of during overhaul. No where is it written that neatest hole works the best, just a big enough hole.
And my last question, when would you cut a concrete roof? Besides the potential dangers associated with that, aren’t there more productive ventilation techniques that could be used than doing a clean breach on the roof?
I used the wrong term, I did some searching and found names like Pyrolight this is an extremely light weight roof material. My point being we found you could be very effective with a saw that you normally would not think effective. This was a drill working with an acquired structure which we had built a pitched roof on top of. This question came up how hard would the building’s roof be to cut. There was much discussion about how we would not like to be on this roof during a fire. Brother this ain’t USAR work this TRUCK work. Get up there, get it open and GET OFF. I know this is a play on terms but as I accidentally used the wrong term light weight concrete, calling a vent hole a clean breach could get some strange results when given as an order. Go ahead and laugh as you picture a Searchcam and Drill headed up the ladder instead of a K-950 and a hook. While seemingly a petty thing such as Rodeo (being a cowboy event) and Rodeo Drive the generation division of the fire service of what is being taught at the fire school and senior men giving the orders has began to show in terminology. For instance while Talking Fire the other day; those of us that actually rode a tailboard and slightly there after know the order, “Engine X come in and fill out Engine XX” means Engine XX was laying a supply line and ran out of hose. Engine X needs to complete the supply line. One of the younger members thought it meant to assist Engine XX on their attack line another had never heard the term. Admittedly something missed by us in training but not something to find out at 3 A.M. when you are expecting the engine to stop at the end of the supply line and it cruises on into the fire. Many would argue it an “old term” and it is, till it’s an order on the radio.
Let’s get back on the roof. Someone looked at me sort of strange when I made a comment about, “You just cut the hole we’ll get the ceiling from underneath.” Whoever wrote you always push the ceiling down after you cut the hole has not went to the same fires as some of us. Two distinct ceiling type’s, shiplap (cut boards nail to the ceiling joists) which you are not going to beat down before you burn up on the roof being one. The other is stucco and wire mesh which you can knock an entire room’s ceiling down in one very heavy piece. Point being, know your territory and building construction and match your techniques accordingly.
Don’t get me wrong, I appreciate the comment, It just raises more questions for me and maybe some other readers too. Be safe